Basic Info.
Model NO.
1200kw load bank manufacturers
Test Region
400V, 6.6kv, 10.5kv, 11kv, 15kv.etc
Application
1MW, 2MW, 4MW, 8MW, 16MW.etc
Customized
Customized
Voltage
AC400V
Frequency
50/60Hz
Max Load Power
1200kw
Power Factor
1
Load Tolerance(Overall)
±3%
Display Precision
0.5 Class
Weight
1500kg
Insulation Grade
F Class
Transport Package
Container
Specification
1200kw
Trademark
triumph load
Origin
China
HS Code
9030339000
Production Capacity
10000set/Year
Product Description
Load Bank Testing 1200kw Load Bank Manufacturers for testing generator
1.Product Introduction
1200KW Resistive Loadbank For Diesel Generator Testing
It is designed for AC power maintenance,could be used widely in communication base,power supply,power station etc.This machine is small,light weight digital table display,easy operation,high intelligence, set the parameters
of constant current discharge process can be done automatically.
![Load Bank Testing 1200kw Load Bank Manufacturers for Testing Generator](http://img9.grofrom.com/www.tllightgroup.com/226f3j00OHTcACtKkFbh/Load-Bank-Testing-1200kw-Load-Bank-Manufacturers-for-Testing-Generator.webp)
![Load Bank Testing 1200kw Load Bank Manufacturers for Testing Generator](http://img9.grofrom.com/www.tllightgroup.com/226f3j00NHtcmnTaEOkV/Load-Bank-Testing-1200kw-Load-Bank-Manufacturers-for-Testing-Generator.webp)
2.1200KW Resistive Loadbank For Diesel Generator Testing Working Environment
Altitute:≤1500m
Temperature:-10°C~50°C
Humidity:≤95%RH
Working Mode:Continuous work(>6hours continuous long-term work per day)
3.1200KW Resistive Loadbank For Diesel Generator Testing Technical Specifications
Technical parameter | |
AC400-1200kW | |
Rated voltage /Frequency | 3 Phase 4 Wire AC 600V/50Hz |
Max load power | Resistive load: 1000kW |
Load step | Resistive load: 14steps; 1, 2, 2, 5, 10, 10, 20, 50, 100, 200, 200, 200, 200, 200kW |
Power factor | 1 |
Load Tolerance(each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power Supply | External AC380V/50Hz 3 phase 4 wire |
Wire Connection | Load Power Supply Input--Copper bar (star connection) Control power supply input--Connector bar |
Insulation grade | F class |
Duty cycle | Continuous |
Cooling | Forced air cooling, Horizontal inlet air, Upward cooling |
Transportation | Hoisting, there are lifting lug in top of casing and casters in bottom of load bank |
Casing Color | Grey(RAL7035) |
Dimension | About 2400 mm*1600mm*1680mm(length*width*height) |
Weight | About 1500kg |
Operating Environment Parameter | |
Ambient Temperature | -10ºC~+50ºC |
Relative Humidity | ≤95% |
Altitude | ≤1500 meters |
Atmospheric Pressure | 86~106kPa |
Main components brand | |
Contactor | Schneider |
Circuit Breaker | Siemens |
Fuse | Delixi |
SCM | Infineon |
Alloy Resistor | Kaixiang |
Data Management Software | Kaixiang |
Hebei Kaixiang Technology was established in 1994, long-term focus on smart power detection technology
development and application in shipbuilding, petroleum, offshore platforms, data centers, communications,
power, military, aviation, research institutes and other areas, and in strict accordance with the ISO9001
international quality standard management system for the design, manufacture and service.
The company's core technologies are independent research, has seven patents, 10 software copyrights, two
corporate standards.Among them, Kaixiang "smart power marine generators AC load," Science and Technology
Department of Hebei Province has been named the international advanced level scientific and technological
achievements, the enterprise standard "dry AC load" to upgrade the industry standard by the Ministry of publicity.
![Load Bank Testing 1200kw Load Bank Manufacturers for Testing Generator](http://img9.grofrom.com/www.tllightgroup.com/226f3j00wIabAETPCyoh/Load-Bank-Testing-1200kw-Load-Bank-Manufacturers-for-Testing-Generator.webp)
![Load Bank Testing 1200kw Load Bank Manufacturers for Testing Generator](http://img9.grofrom.com/www.tllightgroup.com/226f3j00JDacwrQBfFqi/Load-Bank-Testing-1200kw-Load-Bank-Manufacturers-for-Testing-Generator.webp)
![Load Bank Testing 1200kw Load Bank Manufacturers for Testing Generator](http://img9.grofrom.com/www.tllightgroup.com/226f3j00gLMEWCynZhrl/Load-Bank-Testing-1200kw-Load-Bank-Manufacturers-for-Testing-Generator.webp)
4.Why choosing us
The earliest and most professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
The most patent technology and scientific research awards gainer in China.
Advanced detection method and strict inspection procedure build the qualified quality.
Customized production meet the individual requirement.
Prompt delivery & excellent after sales service.
Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Triumph Load is the first brand in the emergency power supply test & maintenance industry in China.
5.Contact Information